Energy systems based on photovoltaic (PV) cells have increased at a rapid pace. Therefore, power converters have been widely employed in power systems to enhance the quality and magnitude of the power drawn from renewable energy sources. An LCL filter for connection of an inverter to the grid is often used to reduce harmonics generated by the inverter. According to different design techniques, optimal parameters of LCL filter tend to vary in a wide range. This paper presents a new approach to an LCL filter. A phase shifting transformer placed in the structure of an LCL filter to minimize harmonic current. Methods and techniques described in this paper are particularly suitable for grid-connected PV power systems.
Published in | American Journal of Electrical Power and Energy Systems (Volume 6, Issue 5) |
DOI | 10.11648/j.epes.20170605.12 |
Page(s) | 72-78 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2017. Published by Science Publishing Group |
Harmonic Mitigation, LCL Filters, PV Sources
[1] | Rashid Niaz Azari, Mohammad Amin Chitsazan, Iman Niazazari. Optimal Recloser Setting, Considering Reliability and Power Quality in Distribution Networks. American Journal of Electrical Power and Energy Systems. Vol. 6, No. 1, 2017, pp. 1-6. |
[2] | M. A. Chitsazan, M. Sami Fadali, Amanda K. Nelson, A. M Trzynadlowski, “Wind speed forecasting using an echo state network with nonlinear output functions”, American Control Conference (ACC), 2017 IEEE, pp. 5306-5311, May. 2017. |
[3] | M. A. Chitsazan, A. M Trzynadlowski, “State estimation of IEEE 14 bus with interphase power controller using WLS method”, Energy Conversion Congress and Exposition (ECCE), 2016 IEEE, pp. 1-5, Sep. 2016. |
[4] | F. Blaabjerg, T. Teodorescu, M. Liserre, and A. V. Timbus, “Overview of control and grid synchronization for distributed power generation systems,” IEEE Trans. Ind. Electron., vol. 53, no. 5, pp. 1398-1409, Oct. 2006. |
[5] | J. He, Y. Li, and M. S. Munir, “A flexible harmonic control approach through voltage-controlled DG-grid interfacing converters,” IEEE Trans. Ind. Electron., vol. 59, no. 1, pp. 444-455, Jan. 2012. |
[6] | M. Liserre, F. Blaabjerg, and S. Hansen, “Design and control of an LCL filter-based three-phase active rectifier”, IEEE Trans. Ind. Appl., vol. 41, no. 5, pp. 1281-1291, Sep./Oct. 2005. |
[7] | Y. Tang, S. Member, P. C. Loh, P. Wang, and F. H. Choo, “Generalized design of high performance shunt active power filter with output LCL filter”, IEEE Trans. Ind. Electron., vol. 59, no. 3, pp. 1443-1452, Mar. 2012. |
[8] | IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, IEEE Std 519-1992, 1993. |
[9] | IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Resources with Electric Power Systems, IEEE Std 1547.1-2005, 2005. |
[10] | F. Huerta, D. Pizarro, S. Cobreces, F. J. Rodriguez, C. Giron, and A. Rodriguez, “LQG servo controller for the current control of LCL grid connected voltage-source converters,” IEEE Trans. Ind. Electron., vol. 59, no. 11, pp. 4272-4284, Nov. 2012. |
[11] | P. Channegowda and V. John, “Filter optimization for grid interactive voltage source inverters”, IEEE Trans. Ind. Electron., vol. 57, no. 12, pp. 4106-4114, Dec. 2010. |
[12] | Y. Tang, P. Loh, P. Wang, F. Choo, F. Gao, and F. Blaabjerg, “Generalized design of high performance shunt active power filter with output LCL-filter”, IEEE Trans. Ind. Electron., vol. 59, no. 3, pp. 1443-1452, Mar. 2012. |
[13] | A. M. Hava, T. A. Lipo, and W. L. Erdman, “Utility interface issues for line connected PWM voltage source converters: a comparative study”, in Proc. of APEC '95, Dallas (USA), pp. 125-132, March 1995. |
[14] | U. N. Khan and T. S. Sidhu, “A phase-shifting transformer protection technique based on directional comparison approach”, IEEE Trans. on Power Delivery, vol. 29, no. 5, pp. 2315-2323, Sep. 2014. |
[15] | J. Bladow and A. Montoya, “Experiences with parallel EHV shifting transformers”, IEEE Trans. on Power Delivery, vol. 6, no. 3, pp. 1096-1100, July 1991. |
[16] | M. A. Chitsazan, G. Gharehpetian, M. Arbabzadeh, “Application of voltage source convector in interphase power controller”, Proc. of World Congress on Engineering and Computer Science (WCECS), vol. 2, pp. 1-6, Oct. 2012. |
[17] | M. A. Chitsazan, A. M Trzynadlowski, “Harmonic mitigation in interphase power controllers using passive filter-based phase shifting transformer”, Energy Conversion Congress and Exposition (ECCE), 2016 IEEE, pp. 1-5, Sep. 2016. |
[18] | Mohammad Amin Chitsazan, Andrzej M. Trzynadlowski. A New Approach to LCL Filter Design for Grid-Connected PV Sources. American Journal of Electrical Power and Energy Systems. Vol. 6, No. 4, 2017, pp. 57-63. |
[19] | A. Reznik, M. G. Simoes, A. Al-Durra, S. M. Muyeen, “Filter design and performance analysis for grid-interconnected systems”, IEEE Trans. on Ind. Appl., vol. 50, no. 2, pp. 1225, 1232, March-April 2014. |
[20] | H. Cha and T.-K. Vu, “Comparative analysis of low-pass output filter for single-phase grid-connected photovoltaic inverter,” in Proc. APEC’10, Palm Springs, CA, pp. 1659-1665, Feb. 2010. |
[21] | F. Bouchafaa, D. Beriber, and M. S. Boucherit, “Modeling and control of a grid connected PV generation system”, in Proc. MED’10, Marrakesh, Morocco, pp. 315-320, Jun. 2010. |
[22] | V. H. Prasad, “Average Current Mode Control of a Voltage Source Inverter Connected to the Grid: Application to Different Filter Cells”, M. S. thesis, Dept. Elect. Eng., Virginia Polytech. Inst. State Univ., Blacksburg, VA, USA, 1997. |
[23] | D. E. Rice, “A detailed analysis of six-pulse converter harmonic currents” IEEE Trans. Ind. Appl., vol. 30, no. 2, pp. 294-304, March/April, 1994. |
[24] | S. V. Araujo, A. Engler, B. Sahan, and F. Antunes, “LCL filter design for grid-connected NPC inverters in offshore wind turbines”, in Proc. ICPE '07, Daegu, S. Korea, pp. 1133-1138, Oct. 2007. |
[25] | M. Grötzbach, and R. Redmann, “Line current harmonics of VS1-fed adjustable-speed drives,” IEEE Trans. Ind. Appl., vol. 36, no. 2, pp. 683-690, March/April, 2000. |
[26] | C. Rech and J. R. Pinheiro, “Line current harmonics reduction in hybrid multilevel converters using phase-shifting transformers,” in Proc. PESC’04, Aachen Germany, pp. 2565-2571, Jun. 2004. |
[27] | D. A. Paice, “Power Electronic Converter Harmonics Multipulse Methods for Clean Power”, IEEE Press, 1996. |
APA Style
Mohammad Amin Chitsazan, Andrzej M. Trzynadlowski. (2017). Harmonic Mitigation in Three-Phase Power Networks with Photovoltaic Energy Sources. American Journal of Electrical Power and Energy Systems, 6(5), 72-78. https://doi.org/10.11648/j.epes.20170605.12
ACS Style
Mohammad Amin Chitsazan; Andrzej M. Trzynadlowski. Harmonic Mitigation in Three-Phase Power Networks with Photovoltaic Energy Sources. Am. J. Electr. Power Energy Syst. 2017, 6(5), 72-78. doi: 10.11648/j.epes.20170605.12
AMA Style
Mohammad Amin Chitsazan, Andrzej M. Trzynadlowski. Harmonic Mitigation in Three-Phase Power Networks with Photovoltaic Energy Sources. Am J Electr Power Energy Syst. 2017;6(5):72-78. doi: 10.11648/j.epes.20170605.12
@article{10.11648/j.epes.20170605.12, author = {Mohammad Amin Chitsazan and Andrzej M. Trzynadlowski}, title = {Harmonic Mitigation in Three-Phase Power Networks with Photovoltaic Energy Sources}, journal = {American Journal of Electrical Power and Energy Systems}, volume = {6}, number = {5}, pages = {72-78}, doi = {10.11648/j.epes.20170605.12}, url = {https://doi.org/10.11648/j.epes.20170605.12}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.epes.20170605.12}, abstract = {Energy systems based on photovoltaic (PV) cells have increased at a rapid pace. Therefore, power converters have been widely employed in power systems to enhance the quality and magnitude of the power drawn from renewable energy sources. An LCL filter for connection of an inverter to the grid is often used to reduce harmonics generated by the inverter. According to different design techniques, optimal parameters of LCL filter tend to vary in a wide range. This paper presents a new approach to an LCL filter. A phase shifting transformer placed in the structure of an LCL filter to minimize harmonic current. Methods and techniques described in this paper are particularly suitable for grid-connected PV power systems.}, year = {2017} }
TY - JOUR T1 - Harmonic Mitigation in Three-Phase Power Networks with Photovoltaic Energy Sources AU - Mohammad Amin Chitsazan AU - Andrzej M. Trzynadlowski Y1 - 2017/08/23 PY - 2017 N1 - https://doi.org/10.11648/j.epes.20170605.12 DO - 10.11648/j.epes.20170605.12 T2 - American Journal of Electrical Power and Energy Systems JF - American Journal of Electrical Power and Energy Systems JO - American Journal of Electrical Power and Energy Systems SP - 72 EP - 78 PB - Science Publishing Group SN - 2326-9200 UR - https://doi.org/10.11648/j.epes.20170605.12 AB - Energy systems based on photovoltaic (PV) cells have increased at a rapid pace. Therefore, power converters have been widely employed in power systems to enhance the quality and magnitude of the power drawn from renewable energy sources. An LCL filter for connection of an inverter to the grid is often used to reduce harmonics generated by the inverter. According to different design techniques, optimal parameters of LCL filter tend to vary in a wide range. This paper presents a new approach to an LCL filter. A phase shifting transformer placed in the structure of an LCL filter to minimize harmonic current. Methods and techniques described in this paper are particularly suitable for grid-connected PV power systems. VL - 6 IS - 5 ER -