Abstract

The electrical power systems are highly non-linear, extremely huge and complex networks. On the other hand, all the developed and countries have not sufficient supply of power. My Project focuses the detection of power failure and takes reflex action to solve the problem with help of GSM communication. The power failure will be detect by relay, and it communicates to Microcontroller to alerts the authorized person. In addition to that, parameters of Generator like Fuel level, Oil level, Temperature, battery status, etc., are monitored and communicated to authorized person. The acquired parameters are processed and recorded in the system memory. If there is any abnormality in their process, according to some predefined instruction and policies that are stored on the embedded system EEPROM then GSM alerts to concerned person immediately.

Published in American Journal of Electrical Power and Energy Systems (Volume 4, Issue 4)
DOI 10.11648/j.epes.20150404.13
Page(s) 45-50
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2015. Published by Science Publishing Group

Keywords

Microcontroller, GSM Modem (SIM 300), Fuel Level (PH606), Oil Level (R Series), Temperature Sensors (LM35)

References
[1] Amit Sachan, “Microcontroller based Based Substation Monitoring and Control System with Gsm Modem” IOSR Journal of Electrical and Electronics Engineering, ISSN: 2278-1676 Volume 1, Issue 6 (July-Aug. 2012).
[2] Mallikarjun Sarsamba “The Load Monitoring and Protection on Electricity Power lines using GSM Network” International Journal of Advanced Research in Computer Science and Software Engineering, Volume 3, Issue 9, September 2013 ISSN: 2277 128X.
[3] S.Vimalraj, Gausalya.R.B, “GSM Based Controlled Switching Circuit between Supply Mains and Captive Power Plant” International Journal of Computational Engineering Research, Vol, 03, Issue, 4.April 2013.
[4] Andriy Palamar “Control System for a Diesel Generator and UPS Based Microgrid”, Scientific Journal of Riga Technical University Power and Electrical Engineering, Volume 27, 2010.
[5] Kwang Seon Ahn “Digital Controller of a Diesel Generator using an Embedded System” International Journal of Information Processing Systems, Vol.2, No.3, December 2006.
[6] Henrik arleving “ways to cut power generator maintanence”the journal, December 2013.
[7] Chetan Patil, Channabasappa Baligar, “Base Transceiver Station (BTS) Safety and Fault Management”, International Journal of Innovative Technology and Exploring Engineering (IJITEE) ISSN: 2278-3075, Volume-3, Issue-7, December 2013.
[8] Y Jaganmohan Reddy, Y V Pavan Kumar, K Padma Raju, Anilkumar Ramsesh, “PLC Based Energy Management and Control Design for an Alternative Energy Power System with Improved Power Quality”, International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 Vol. 3, Issue 3, May-Jun 2013.
[9] Alper T. Alan “A Field Study of Human-Agent Interaction for Electricity Tariff Switching”, Agents, Interaction and Complexity Group, University of Southampton, Southampton, UK.
[10] J. Pierce and E. Paulos. Beyond energy monitors: interaction, energy, and emerging energy systems. In Proc. CHI’12. ACM, 2012.
Cite This Article
  • APA Style

    S. Boopathi, M. Jagadeeshraja, L. Manivannan, M. Dhanasu. (2015). Smart Generator Monitoring System in Industry Using Microcontroller. American Journal of Electrical Power and Energy Systems, 4(4), 45-50. https://doi.org/10.11648/j.epes.20150404.13

    Copy | Download

    ACS Style

    S. Boopathi; M. Jagadeeshraja; L. Manivannan; M. Dhanasu. Smart Generator Monitoring System in Industry Using Microcontroller. Am. J. Electr. Power Energy Syst. 2015, 4(4), 45-50. doi: 10.11648/j.epes.20150404.13

    Copy | Download

    AMA Style

    S. Boopathi, M. Jagadeeshraja, L. Manivannan, M. Dhanasu. Smart Generator Monitoring System in Industry Using Microcontroller. Am J Electr Power Energy Syst. 2015;4(4):45-50. doi: 10.11648/j.epes.20150404.13

    Copy | Download

  • @article{10.11648/j.epes.20150404.13,
      author = {S. Boopathi and M. Jagadeeshraja and L. Manivannan and M. Dhanasu},
      title = {Smart Generator Monitoring System in Industry Using Microcontroller},
      journal = {American Journal of Electrical Power and Energy Systems},
      volume = {4},
      number = {4},
      pages = {45-50},
      doi = {10.11648/j.epes.20150404.13},
      url = {https://doi.org/10.11648/j.epes.20150404.13},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.epes.20150404.13},
      abstract = {The electrical power systems are highly non-linear, extremely huge and complex networks. On the other hand, all the developed and countries have not sufficient supply of power. My Project focuses the detection of power failure and takes reflex action to solve the problem with help of GSM communication. The power failure will be detect by relay, and it communicates to Microcontroller to alerts the authorized person. In addition to that, parameters of Generator like Fuel level, Oil level, Temperature, battery status, etc., are monitored and communicated to authorized person. The acquired parameters are processed and recorded in the system memory. If there is any abnormality in their process, according to some predefined instruction and policies that are stored on the embedded system EEPROM then GSM alerts to concerned person immediately.},
     year = {2015}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Smart Generator Monitoring System in Industry Using Microcontroller
    AU  - S. Boopathi
    AU  - M. Jagadeeshraja
    AU  - L. Manivannan
    AU  - M. Dhanasu
    Y1  - 2015/06/06
    PY  - 2015
    N1  - https://doi.org/10.11648/j.epes.20150404.13
    DO  - 10.11648/j.epes.20150404.13
    T2  - American Journal of Electrical Power and Energy Systems
    JF  - American Journal of Electrical Power and Energy Systems
    JO  - American Journal of Electrical Power and Energy Systems
    SP  - 45
    EP  - 50
    PB  - Science Publishing Group
    SN  - 2326-9200
    UR  - https://doi.org/10.11648/j.epes.20150404.13
    AB  - The electrical power systems are highly non-linear, extremely huge and complex networks. On the other hand, all the developed and countries have not sufficient supply of power. My Project focuses the detection of power failure and takes reflex action to solve the problem with help of GSM communication. The power failure will be detect by relay, and it communicates to Microcontroller to alerts the authorized person. In addition to that, parameters of Generator like Fuel level, Oil level, Temperature, battery status, etc., are monitored and communicated to authorized person. The acquired parameters are processed and recorded in the system memory. If there is any abnormality in their process, according to some predefined instruction and policies that are stored on the embedded system EEPROM then GSM alerts to concerned person immediately.
    VL  - 4
    IS  - 4
    ER  - 

    Copy | Download

Author Information
  • Embedded System Technologies, Knowledge Institute of Technology, Tamilnadu, India

  • Department of Electrical and Electronics Engineering, Knowledge Institute of Technology, Tamilnadu, India

  • Department of Electrical and Electronics Engineering, Knowledge Institute of Technology, Tamilnadu, India

  • Steel Authority of India, Tamilnadu, India

  • Sections