Source-to-Hood Alignment Effects on Ammonia Dispersion and Capture Performance in an Engine-Room Test Bed

Published: October 14, 2026
Views:       Downloads:
Abstract

Ammonia is a promising carbon-free marine fuel, but accidental leakage in enclosed engine rooms can generate persistent toxic clouds and severe breathing-zone exposure. Conventional ventilation assessment based only on nominal exhaust capacity or air-change rate may not adequately represent hood capture performance, particularly when the leak jet is not aligned with the suction region. In this study, eighteen transient three-dimensional CFD simulations were conducted for a full-scale ammonia engine-room test bed by varying leak location, hood type, and hood height. The results show that source-to-hood alignment strongly controls early plume capture and long-term residual contamination. The well aligned IE-T3-H6 case achieved a removal efficiency of 98.77% with only 0.05 kg NH3 remaining at 180 s, whereas the poorly aligned VALVE-T3-H6 case achieved only 38.30% removal and retained 2.51 kg NH3. In the worst case, the 30 ppm toxic cloud expanded to nearly the full compartment volume, and the breathing-zone average concentration remained above 30 ppm until approximately 913.5 s. These findings demonstrate that hood ventilation performance should be evaluated using toxic cloud volume, breathing-zone exposure, residual mass, and capture delay even under an identical exhaust-flow basis.

Published in Abstract Book of ICEER2026 & ICCIVIL2026
Page(s) 17-17
Creative Commons

This is an Open Access abstract, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2026. Published by Science Publishing Group

Keywords

Ammonia Dispersion, Ventilation Hood Efficiency, Computational Fluid Dynamic, Toxic Cloud Evolution, Breathing-zone Exposure, Toxic in the Engine Room

Acknowledgments
This research was supported by Korea Evaluation Institute of Industrial Technology (KEIT) grant funded by the Ministry of Trade, Industry and Energy (MOTIE) (RS-2023-00285272, RS 2024 00434535 and RS-2024-00458498). This work was supported by Korea Institute for Advancement of Technology (KIAT) grant funded by the Korean Government (MOTIE) (RS-2025-02215617, HRD Program for Industrial Innovation).